High Frequency Online UPS

H Series 1KVA to 3KVA High Frequency Online UPS

Key features: H series on-line UPS is an advanced true double conversion on-line topology the H series isolated gate bipolar transistors (IGBT) for true isolation from AC input.Ideal for data centers in network and industrial applications.
Key features:
 
 
H series on-line UPS is an advanced true double conversion on-line topology, the H series isolated gate bipolar transistors (IGBT) for true isolation from AC input. Ideal for data centers in network and industrial applications. Features scalable battery packs for those critical business systems that require long run times. With the H series wide in-put voltage range and near zero tolerance on frequency and voltage variance on the put-put the H series is perfect for the most demanding and delicate of applications.
 
 
►Sine-wave output
True sine-wave output with less than 3% THD
 
►Double conversion design
Zero transfer/complete isolation of input AC
 
►UPS monitoring software
Powerful true RS232 communication via the enclosed software manages and safely shutdown operating systems.
 
►Network RJ45/11 protection
Completed powerful network and phone line surge protection
 
►AC surge suppressor
Powerful multi-stage surge components exceed IEEE requirements.
 
►SNMP slot option
Allows for remote monitoring and control via www
 
►Sleep mode
Worry free battery management. The unit turns itself off after ten seconds to conserve battery power when no power needs are detected.
 
►Battery level indicators
LED's indicate battery levels
 
►Load sensing
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.
 
►Low battery indicators
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.
 
►Replace battery indicators
A preventative measure that indicates when batteries must be replaced to prevent server crashes.  
Technical specifications:
 
 

Model H1KS H2KS H3KS
Rated power VA/W 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW
Input Nominal voltage 220VAC
Voltage range 115~300VAC
Frequency range 46~54Hz(default), user adjustable within 40~60Hz
Power efficiency 0.97
Connection IEC320-10A inlet IEC320-16A inlet
Output Voltage 220VAC±2%
Frequency 46~54Hz or 50Hz±0.2(line mode)
50Hz±0.2Hz(battery mode)
Waveform Pure sine wave
Distortion 3% 4%
Overload capability 108%~150% for 30 sec., 150% for 300ms
Current crest ratio 3:1
Connection IEC320*4 IEC320*6 IEC320*3 and
terminal block
Battery Type Sealed, maintenance free, lead-acid
Quantity 3 pieces 6 pieces 8 pieces
Back-up time(full load) 5 min 9 min 5 min
Recharge time 5 hrs to 90% of capacity after full load discharge
Bypass Automatic transfer On overload and UPS failure
Before UPS power-on Default “NO”, user adjustable to “YES”
Voltage range 80~264VAC(default), user adjustable within 80~286VAC
Transfer time 0 ms; less than 4ms from inverter to bypass and vice versa
LED indicators Status Load level/battery level, battery , utility power, inverter, bypass, overload, fault
Audible alarm Bypass, on battery mode, battery low, overload, fault
Acoustic noise At 1 meter distance 45 dB 50 dB
Communication DB-9 port RS-232 serial interface
Intelligent slot Options: Webpower, AS400 card or Winpower CMC
Network surge protection RJ45 I/O port available for network or fax/modem
Environmental Operating temperature 0~40°C
Operating humidity 20~90% non-condensing
Weight Net(Kg) 13 31.5 32
Dimension WxDxH(mm) 145x400x220 192x460x348
 
Model H1KL H2KL H3KL
Rated power VA/W 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW
Input Nominal voltage 220VAC
Voltage range 115~300VAC
Frequency range 46~54Hz(default), user adjustable within 40~60Hz
Power factor 0.97
Connection IEC320-10A inlet IEC320-16A inlet
Output Voltage 220VAC±2%
Frequency 46~54Hz or 50Hz±0.2(line mode)
50Hz±0.2Hz(battery mode)
Waveform Pure sine wave
Distortion 3% 4%
Overload Capability 108%~150% for 30 sec., 150% for 300ms
Current crest ratio 3:1
Connection IEC320-10A*4 IEC320-10A*6 IEC320-10A*3 and
terminal block
Battery Type Sealed, maintenance free, lead-acid
Nominal DC voltage 36VDC 96VDC 96VDC
Back-up time Depends on the capacity of the external battery bank
Connection External battery socket
Bypass Automatic transfer On overload and UPS failure
Before UPS power-on Default “NO”, user adjustable to “YES”
Voltage range 80~264VAC(default), user adjustable within 80~ 286VAC
Transfer time 0 ms; less than 4 ms from inverter to bypass and vice versa
LED indicators Status Load level/battery level, battery, utility power, inverter, bypass, overload, fault
Audible alarm Bypass, on battery mode, battery low, overload, fault
Acoustic noise At 1 meter distance 45 dB 50 dB
Communication DB-9 port RS-232 serial interface
Intelligent slot Options: WebPower, AS400 card or WinPower CMC
Network surge protection RJ45 I/O port available for 10 base-T network or fax/modem
Environmental Operating temperature 0~40°C
Operating humidity 20~90% non-condensing
Weight Net(Kg) 7 13.5 14
Dimension W x D x H(mm) 145x400x220 192x460x348